EtherSens ProSuite with touch-display


























The complete and flexible solution for monitoring, controlling and analyzing industrial processes
WIFI operating as a client or access-point
IO-modules direct pluggable
Configuration via web-server or integrated
touch-display
Supply: 24V DC
- Integrated 2.4" capacitive touch-display with 32768 colors
- Integrated IO-bus => ideal for extensions of all kinds
- Standard IO-modules available from stock(see tab "Options/Accessories")
- An IO-module for special application
- Ask us about your configured IO-module
more...
ARTNR: 9201-PROSUITE-TDIS
EtherSens ProSuite with touch-display
| EAN number: | 4260721031240 | |
| HS-code: | 85423190 | |
| Weight: | 0.3 kg |
Alternativen
EtherSens ProSuite with touch-display
WIFI operating as a client or access-point IO-modules direct pluggable Configuration via web-server or integrated touch-display Supply: 24V DC
plus VAT. and shipping
Retrofitting LTE-modem for EtS-ProSuite
Retrofitting LTE-modem for EtherSens-ProSuite Send/receive of SMS-messages Communication from/into internet
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
Extension 4xDig.In - 5x Dig.Out - 4x Ana.In
Extension-module for EtherSens-ProSuite 4x digital IN (com. GND, max. 24V DC) 5x digital OUT (com. Supply max. 80V) 4x Analog IN (0..30V, 0/4..20mA, differential) [16 bit] Supply from IO-Bus
plus VAT. and shipping
Extension OSC for EtherSens-ProSuite
Module for oxygen analysis function detects EMK, temperature voltage and controls heating of the measuring probe Zirconium dioxide probe optionally Power supply from EtherSens ProSuite IO bus-connection
plus VAT. and shipping
Extension SMART-RELAY for EtherSens-ProSuite
Measure current/voltage/energy values without Rogowski coil or split core TCP/IP controlled relay ON/OFF Power supply from EtherSens ProSuite IO bus-connection
plus VAT. and shipping
Extension Energy for EtherSens ProSuite
Extension-module for EtherSens-ProSuite Energy-analysis (EN 50470-1 EN 50470-3) L1, L2, L3, N realtime analysis Up to 8000 measurements / second Hz / cos phi / power-factor Energy consumption kWh For Rogwski-coils up to 0,5V Power supply from EtherSens ProSuite IO bus-connection
plus VAT. and shipping
Gyro-Sensor 312 for EtherSens
Measuring range: ±1.5g / ±3g / ±6g / ±12g 3.3V DC supply (from I2C-interfaceport) I2C-connection 1m
plus VAT. and shipping
Gyro-Sensor 313 for EtherSens
Measuring range: ±0.5g / ±1g / ±2g / ±4g 3.3V DC supply (from I2C-interfaceport) I2C-connection 1m
plus VAT. and shipping
Segment-display for EtherSens
4 Digit 14 segment-display WHITE 0,56" high in wall-mounting case 5V DC supply (from I2C-interfaceport) I2C-connection
plus VAT. and shipping
Sun-light-sensor for EtherSens
max. 220k Lux (switchable ranges) 3.3V DC supply (from I2C-interfaceport) I2C-connection 1m
plus VAT. and shipping
Temp./humidity/air-pressure for EtherSens
Measuring range: Temperature: -40 ...+85°C Humidity: 0...100% relative Feuchte Pressure: 300...1100 hPa 3.3V DC supply (from I2C-interfaceport) I2C-connection 1m
plus VAT. and shipping
EtherSens ProSuite
WIFI operating as a client or access-point IO-modules direct pluggable Configuration via web-server Supply: 24V DC
plus VAT. and shipping
EtherSens ProSuite LTE
Integrated LTE-modem 4G WIFI operating as a client or access-point IO-modules direct pluggable Configuration via web-server Supply: 24V DC
plus VAT. and shipping
EtherSens ProSuite LTE with touch-display
Integrated LTE-modem 4G WIFI operating as a client or access-point IO-modules direct pluggable Configuration via web-server or integrated touch-display Supply: 24V DC
plus VAT. and shipping
Option DB backup/restore as CSV
Function extension DB backup/restore: The extracted data block is converted with the source file from Simatic-Manager/TIA. into a CSV-file and saved.
plus VAT. and shipping
Option PLC-message with additional text
Function extension PLC-message sending: PLC-messages from the PLC are enhanced with text blocks from the SD card and sent.
plus VAT. and shipping
- Integrated 2.4" capacitive touch-display with 32768 colors
- Integrated IO-bus => ideal for extensions of all kinds
- Standard IO-modules available from stock(see tab "Options/Accessories")
- An IO-module for special application
- Ask us about your configured IO-module
- Energy recording:
- precise measurement and monitoring of energy consumption
- L1, L2, L3, N real-time analysis
- up to 8000 measurements / second
- Hz / cos phi / power factor
- power consumption kWh
- PLC fault message dispatch (SMS/Email):
- real-time notifications of system failures via SMS and email
- message text generated by the device or in the PLC
- PLC data logger:
- long-term recording of process data for analysis and optimization
- backup data to SD-card, USB-stick or network drive
- Protocol converter:
- Enables integration and communication between different protocols (S5 / S7 / L1 / Modbus)
- Gas-analysis:
- monitoring and analysis of gases for environmental and safety applications
- determination of residual oxygen content in processes/process gases)
- Small control:
- flexible control for small to medium-sized automation projects
- Digital/Analog IO:
- support for a variety of input and output signals, both digital and analog
- Sunlight sensor:
- detection of light intensity to control lighting and energy saving systems
- Gyro sensor:
- detection of rotary movements for applications in automation and navigation
- Temp./Air flow/Air pressure sensor:
- combined sensor for measuring temperature, humidity and air pressure
- Segment display:
- simple and clear display of numerical values and status information
- Touchdisplay:
- intuitive operation and visualization of system information and control functions
- S5/S7-PLC-data secure/restore hardware-independently:
- secure backup and recovery of S7 PLC blocks regardless of hardware
S5: over S5-LAN++
S7: over S7-LAN++ [MPI, Profibus] or directy over Ethernet-/Profinet-CP
- secure backup and recovery of S7 PLC blocks regardless of hardware
- Directly to/from USB-Stick universally via PLC trigger:
- Simple and universal data transfer using PLC trigger directly to or from a USB-stick
- Sends alarm-messages controlled by the PLC
- Receiver in the PLC deposited, so ONLINE replaceable
- Messages in the PLC deposited, so ONLINE replaceable
- Backup/Restore of S5/S7-block as binary file on SD-card, USB-stick or SMB-directory
- S5: over S5-LAN++-module
- S7: over S7-LAN++-module or Ethernet-/Profinet-CP
- Communikation with a controller via optional IO-modules, LTE or via network S7-TCPIP RFC1006
- S7-SPS over S7-LAN++-module
- S5-PLC over S5-LAN++-module
- Solve control-tasks via integrated logic-module
- Implementation of different protocols, for e.g. L1-bus-communication via RFC1006, Modbus
- Coupling of multiple devices to a network
- Coupling with WinCC and access to process values
Application-examples (only german language):
At Step5 the Step5-software is going to be patched, then working with the virtual Com-Port will be also possible.
Via digital input triggered DB-backup/-restore without additional PC via PG-socket and Ethernet to FTP-server
S5-PLC triggered DB-backup/-restore without additional PC via PG-socket and Ethernet on FTP-server
Via digital input triggered DB-backup/-restore without additional PC via PG-socket and Ethernet to SD-card
S5-PLC triggered DB-backup/-restore without additional PC via PG-socket and Ethernet on SD-card
Via digital input triggered DB-backup/-restore without additional PC via PG-socket and Ethernet to USB-stick
S5-PLC triggered DB-backup/-restore without additional PC via PG-socket and Ethernet on USB-stick
Via digital input triggered DB-backup/-restore without additional PC via PN-port to FTP-server
S7-PLC triggered DB-backup/-restore without additional PC via PN-port on FTP-server
Via digital input triggered DB-backup/-restore without additional PC via PN-port to SD-card
S7-PLC triggered DB-backup/-restore without additional PC via PN-port on SD card
Via digital input triggered DB-backup/-restore without additional PC via PN-port to USB-stick
S7-PLC triggered DB-backup/-restore without additional PC via PN-port to USB-stick
Via digital input triggered DB-backup/-restore without additional PC via MPI/Profibus to FTP-server
S7-PLC triggered DB-backup/-restore without additional PC via MPI/Profibus on FTP-server
Via digital input triggered DB-backup/-restore without additional PC via MPI/Profibus to SD-card
S7-PLC triggered DB-backup/-restore without additional PC via MPI/Profibus on SD-card
Via digital input triggered DB-backup/-restore without additional PC via MPI/Profibus to USB-stick
S7-PLC triggered DB-backup/-restore without additional PC via MPI/Profibus on USB-stick
Send directly from your PLC news, statuses, alarms as SMS or email.
| Supply voltage: | 24V DC +/- 20% |
| Power consumption: | 2 watt |
| Display: |
WEB-Browser 1 status LED bicolor Touch-display |
| Touch-Display: |
2.4" capacitive touch-display 320 x 240 pixel (QVGA) TFT, IPS with 32768 colors |
| Handling/Configuration: |
WEB-Browser Touch-display |
| Interfaces: |
Slot for microSD Antenna-connector SMA(f) (2.4 GHz IEEE 802.11b/g) 10/100BaseTX RJ45-ethernet-plug Button for factory settings USB-port type A |
| Overvoltage category: | CAT IV |
|
Insulation value network <=> mains voltage: |
1,5 KV |
| Operating temperature: | -30 - +55°C |
| Case: | ABS-plastic case V0 |
| Dimensions: |
108 x 90 x 67 mm |
| Scope of delivery: |
EtherSens ProSuite with touch-display WIFI-stub-antenna Power-Plug 2pin |
sensors:
Extension 4xDig.In - 5x Dig.Out - 4x Ana.In
Extension-module for EtherSens-ProSuite 4x digital IN (com. GND, max. 24V DC) 5x digital OUT (com. Supply max. 80V) 4x Analog IN (0..30V, 0/4..20mA, differential) [16 bit] Supply from IO-Bus
plus VAT. and shipping
Extension OSC for EtherSens-ProSuite
Module for oxygen analysis function detects EMK, temperature voltage and controls heating of the measuring probe Zirconium dioxide probe optionally Power supply from EtherSens ProSuite IO bus-connection
plus VAT. and shipping
Extension SMART-RELAY for EtherSens-ProSuite
Measure current/voltage/energy values without Rogowski coil or split core TCP/IP controlled relay ON/OFF Power supply from EtherSens ProSuite IO bus-connection
plus VAT. and shipping
Extension Energy for EtherSens ProSuite
Extension-module for EtherSens-ProSuite Energy-analysis (EN 50470-1 EN 50470-3) L1, L2, L3, N realtime analysis Up to 8000 measurements / second Hz / cos phi / power-factor Energy consumption kWh For Rogwski-coils up to 0,5V Power supply from EtherSens ProSuite IO bus-connection
plus VAT. and shipping
Gyro-Sensor 312 for EtherSens
Measuring range: ±1.5g / ±3g / ±6g / ±12g 3.3V DC supply (from I2C-interfaceport) I2C-connection 1m
plus VAT. and shipping
Gyro-Sensor 313 for EtherSens
Measuring range: ±0.5g / ±1g / ±2g / ±4g 3.3V DC supply (from I2C-interfaceport) I2C-connection 1m
plus VAT. and shipping
Segment-display for EtherSens
4 Digit 14 segment-display WHITE 0,56" high in wall-mounting case 5V DC supply (from I2C-interfaceport) I2C-connection
plus VAT. and shipping
Sun-light-sensor for EtherSens
max. 220k Lux (switchable ranges) 3.3V DC supply (from I2C-interfaceport) I2C-connection 1m
plus VAT. and shipping
Temp./humidity/air-pressure for EtherSens
Measuring range: Temperature: -40 ...+85°C Humidity: 0...100% relative Feuchte Pressure: 300...1100 hPa 3.3V DC supply (from I2C-interfaceport) I2C-connection 1m
plus VAT. and shipping
options:
Option DB backup/restore as CSV
Function extension DB backup/restore: The extracted data block is converted with the source file from Simatic-Manager/TIA. into a CSV-file and saved.
plus VAT. and shipping
Option PLC-message with additional text
Function extension PLC-message sending: PLC-messages from the PLC are enhanced with text blocks from the SD card and sent.
plus VAT. and shipping
accessories:
Retrofitting LTE-modem for EtS-ProSuite
Retrofitting LTE-modem for EtherSens-ProSuite Send/receive of SMS-messages Communication from/into internet
plus VAT. and shipping
plus VAT. and shipping
Cross-cable 3m Cat5+, shielded
RJ45 plug <=> RJ45 plug, twisted pinning
Patch-cable 3m, Cat5+, shielded
RJ45 plug <=> RJ45 plug, 1:1
Patch-cable 0.25m, Cat5e, shielded
RJ45 plug <=> RJ45 plug, 1:1
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
EtherSens ProSuite with touch-display
WIFI operating as a client or access-point IO-modules direct pluggable Configuration via web-server or integrated touch-display Supply: 24V DC
plus VAT. and shipping
EtherSens ProSuite
WIFI operating as a client or access-point IO-modules direct pluggable Configuration via web-server Supply: 24V DC
plus VAT. and shipping
EtherSens ProSuite LTE
Integrated LTE-modem 4G WIFI operating as a client or access-point IO-modules direct pluggable Configuration via web-server Supply: 24V DC
plus VAT. and shipping
EtherSens ProSuite LTE with touch-display
Integrated LTE-modem 4G WIFI operating as a client or access-point IO-modules direct pluggable Configuration via web-server or integrated touch-display Supply: 24V DC
plus VAT. and shipping
EtherSens
EtherSens EnergyCollect energy data +++ Log energy data +++ PLC fault message dispatch +++ PLC data logging/saving +++ Implement control tasks +++ Configuration via webinterface
EtherSens ControlCapture Dig/Analog-IO +++ Log Dig/Analog-IO +++ PLC fault message-dispatch +++ PLC-data logging/saving +++ implement control-tasks +++ Datalogger with web-server +++ Digital/analogue onboard-IO
EtherSens BasicPLC fault message dispatch +++ PLC data logging/saving +++ implement control tasks +++ Universal solution per task +++ Web page parameterization +++ EtherSens Basic
EtherSens OxygenCapture of gas-values +++ Monitor of gas-values +++ PLC-fault messaging +++ PLC-data logging/saving +++ Convert control tasks
MONI mobile netanalyser EN 50470-1 / EN 50470-3load studies +++ energy checks +++ collect energy data +++ Log energy data +++ PLC fault message dispatch +++ PLC-data logging/saving +++ implement control-tasks +++ EN50470-1 / EN50470-3
EtherSens ProSuiteThe complete and flexible solution for monitoring, controlling and analyzing industrial processes
EtherSens ProSuite LTEThe complete and flexible solution with LTE for monitoring, controlling and analyzing industrial processes
EtherSens ProSuite LTE with touch-displayThe complete and flexible solution with LTE for monitoring, controlling and analyzing industrial processes





PI-Service-Mail

ask technician:
same day