Functionality / use
DLL / library for data exchange between PC and SIMATIC S7 under Windows (any)/Linux.

Supported interfaces:
- PC / MPI adapter for S7 300/400 (PC baud rate up to 115 kB, PLC baud rate up to
- PC-PPI adapter for S7 200 (PC / PLC baud rate 9.6 kB or 19.2 kB)
Support for virtually all programming languages.

With simple functions, the user can quickly access the data PLCs in the network using C, C ++, Delphi, Visual Basic or Excel. Only the MPI address of the PLC is required for coupling. Flags, inputs, outputs, data blocks, timers and counters of the PLC can be read or written access immediately.
No program change is necessary in the PLC!


more...

Functionality / use
DLL / library for data exchange between PC and SIMATIC S7 under Windows (any)/Linux.

Supported interfaces:
- PC / MPI adapter for S7 300/400 (PC baud rate up to 115 kB, PLC baud rate up to
- PC-PPI adapter for S7 200 (PC / PLC baud rate 9.6 kB or 19.2 kB)
Support for virtually all programming languages.

With simple functions, the user can quickly access the data PLCs in the network using C, C ++, Delphi, Visual Basic or Excel. Only the MPI address of the PLC is required for coupling. Flags, inputs, outputs, data blocks, timers and counters of the PLC can be read or written access immediately.
No program change is necessary in the PLC!

Features
function Description / purpose

ES7Open

Used to initialize the serial interface. At this point there is still no check whether the PLC is present.
Warning: The MPI connection is only started automatically when the read or write functions are called up.
It is also checked whether the baud rate and local MPI address are identical with a possibly preceding "ES7Open".
To be able to access several PLCs in the same MPI bus, an "ES7Open" must be carried out for each PLC. However, with the corresponding PLC MPI address.

ES7Close

Closes the connection identified by Ref. If necessary, the serial interface is also closed here

ES7RdW

read word by word from the PLC (I, Q, M, DB)

ES7RdB

read from the PLC byte by byte (E, A, M)

ES7WrW

write word by word to the PLC (I, Q, M, DB)

ES7WrB

write to the PLC byte by byte (E, A, M)

ES7RdDW

Read from the PLC in double words (I, Q, M, DB, T)

ES7WrDW

write to the PLC in double words (I, Q, M, DB, T)

ES7RdReal

Read real (floating point number) (E, A, M, DB)

ES7WrReal

Write real (floating point number) (E, A, M, DB)

ES7RdBit

Read a bit (M, A, E)

ES7SetBit

Set a bit (M, A, E) to "1".

ES7ResetBit

Set a bit (M, A, E) to "0".


Requirements / technical data
operating system

Windows (any) upto WinXP, LINUX, MS-DOS

Delivery form DLL or LIB module, optionally also in C / C ++ source code
supported programming languages or compilers

· MS Visual C/C++
· Borland C/C++
· Visual Basic
· Delphi
· VB-Script (=Excel, Word, Access)
· KDE (Linux)
· for MS-DOS: MS-C, Borland-C, Turbo-Pascal (partly on request)

Connection medium PC/MPI-adapter (Siemens) or our PC/MPI-cable (order number 9350) Connection to the PC RS232 on the PLC MPI-bus
Transmission
speed
9600,19200, 38400 Bit/s
with our cable also 57600 bit / s
PLC types SIMATIC S7 200/300/400

Licenses:
Project License Single Developer License Site / Branch / Standort License Sourcecode License School License
  • Only one project may be realized with this license and implemented
  • Further projects requires further project licenses
  • one registered developer may use the SDK
  • all products/applications developed with the SDK may be delivered to your users/customers in unlimited numbers and used by them (Royalty Free)
  • the term of the license is unlimited
  • ideal for mass-produced products
  • applies to a single registered developer
  • the term of the license is unlimited

  • unlimited number of developers in this location are allowed to use the SDK
  • all products/applications developed with the SDK may be delivered to your users/customers in unlimited numbers and used by them (Royalty Free)
  • the term of the license is unlimited
  • ideal for mass-produced products
  • applies to a developer location (= one postal address where development takes place)
  • the term of the license is unlimited

  • Sourcecode of the driver

  • Use for school and educational purposes only
  • No realization of commercial projects

All prices plus costs of delivery, shipping insurance and VAT.
All prices plus costs of delivery, shipping insurance and VAT.

S7-communication-driver over COM-Port

S7-communication-driver COM-Port for Linux
All prices plus costs of delivery, shipping insurance and VAT.

Automatic-mode

Versionstory

Other downloads

Extension

Support-videos